The nonlinear currents generated by the massive use of modern power and electric equipment are impacting the power grid and aggravate its pollution in the harmonic form, cause overload failures to capacitors, transformers and transmission devices and generate serious interference to measuring, transmitting and calculating devices; in addition, resonance and voltage distortions may also result in power supply accidents. Series reactors could effectively improve or avoid such problems. After installing the capacitor and reactor in series, the resonance frequency is lower than the minimum of the system (usually 5th and 7th waves), so that compatibility is showed under power frequency and power factor is improved; meanwhile, there is no need to worry about the amplification of harmonic wave. With satisfactory impedance matching, the capacitor bank could absorb 30% to 60% of the harmonic currents (5th harmonic wave, for example).

■     Product Application

  • Operating frequency:50Hz-60Hz
  • Rated operating current:5A-2000A
  •  Rated operating voltage:220V-10KV
  • Temperature rise:≤95K
  • Noise:≤65dB
  • Three-phase equilibrium degree:-5%…+5%
  • Reactive Strength:core-winding3000VAC/50Hz/5mA/10s free of arcing breakage(ftested in factory)
  •  Insulation Resistance:1000VDC,insulation resistance≥100MΩ
  •  Degree of protection:IP00-IP20
  •  Reduction factor:5,67%,7%,14%
  • Pn Performance range Pn:5Kvar…100kvar
  • Monitoring:temperature switch is integrated,contacts are fitted on terminals.
  •  Temperature classes:ta40℃/F,H
  •  Installation altitude:≤2000m above sea level
  • Storage temperature:-25℃…+55℃
  • Transport temperature:-25℃…+70℃
  • Permissible humidity rating:humidity 5%…95% occasional condensation permissible

■   Applicable Standards

  • IEC289:1987 Reactor
  • GB10229-88 Reactor(eqvIEC289:1987)
  • JB9644-1999 Reactor used for semiconductor electrical driving


■   Product Identification Code


        


■   Product Size



                         

    Choking factor p = 5.67 %, L = constant to 1.82 · Ithmax, fRES = 210 Hz

Order No Picture 
NO.

Filter
bank
capacity QC
kvar

 Inductance

(mH)

Dimensions

(L*W*H)

Mounting 
dimensions

    (D1*W1)  

Rated 
Current

      (A)   

Connections
K = Terminal
F = Flat
termination

Total weight per
PU approx.

(KG)

ATR002800400SA05.67X A 5 6.12 195*100*210 120*72 8.0 K 3.7
ATR004300400SA05.67X A 7.5 4.081 195*100*210 120*92 12.0 K 5
ATR005700400SA05.67X A 10 3.06 195*150*165 120*92 16.0 K 6.4
ATR007100400SA05.67X A 12.5 2.45 195*165*165 120*112 20.0 K 9.1
ATR0085000400SA05.67X A 15 2.04 195*165*165 120*112 24.0 K 9.3
ATR011300400SA05.67X A 20 1.53 230*160*185 150*95 32.0 K 13
ATR014200400SA05.67B A 25 1.22 250*165*200 182*95 40.0 K 18.3
ATR017000400SA05.67B B 30 1.02 250*170*200 182*105 50.0 F 18
ATR022700400SA05.67B B 40 0.77 250*180*200 182*115 65.0 F 25.3
ATR028400400SA05.67B B 50 0.61 290*185*220 214*118 80.0 F 34.1
ATR034000400SA05.67B B 60 0.51 290*200*200 214*128 95.0 F 35.6
ATR045400400SA05.67B B 80 0.38 320*205*285 243*130 130.0 F 42
ATR051000400SA05.67B B 90 0.34 320*210*310 243*135 145.0 F 47
ATR056700400SA05.67B B 100 0.31 320*220**310 243*140 160.0 F 51.9

Choking factor p = 7 %, L = constant to 1.66 · Ithmax, fRES = 189 Hz

Order No   Picture 
NO.

Filter
bank
capacity QC
kvar

 Inductance

(mH)

 Dimensions

 (L*W*H)  

 Mounting 
dimensions

    (D1*W1)

Rated 
Current

(A)

Connections
K = Terminal
F = Flat
termination

Total weight per
PU approx.

(KG)


ATR003500400SA07X A 5 7.2 195*100*210 120*72 7.5 K 3.3
ATR005300400SA07X A 7.5 5 195*100*210 120*92 11 K 4.8
ATR007000400SA07X A 10 3.8 195*150*165 120*92 15 K 5.9
ATR008800400SA07X A 12.5 3 195*165*165 120*112 19 K 8.6
ATR010500400SA07X A 15 2.5 195*165*165 120*112 23 K 8.8
ATR014000400SA07X A 20 1.8 230*160*185 150*95 30 K 12.8
ATR017500400SA07B B 25 1.4 250*165*200 182*95 38 K 19.1
ATR021000400SA07B B 30 1.2 250*170*200 182*105 45 F 19.6
ATR028000400SA07B B 40 0.95 250*180*200 182*115 60 F 24.7
ATR035000400SA07B B 50 0.75 290*185*220 214*118 75 F 26.5
ATR042000400SA07B B 60 0.62 290*200*220 214*128 90 F 34.1
ATR056000400SA07B B 80 0.46 320*205*285 243*130 122 F 40
ATR063000400SA07B B 90 0.43 320*210*310 243*135 130 F 45
ATR070000400SA07B B 100 0.37 320*220*310 243*140 150 F 50

Choking factor p = 14 %, L = constant to 1.4 · Ithmax, fRES = 134 Hz

Order No     Picture 
NO.

bank
capacity QC
kvar

 Inductance

     Dimensions

    (L*W*H)    

  Mounting 
dimensions

  (D1*W1)   

 Rated 
Current

   (A)

Connections
K = Terminal
F = Flat
termination

Total weight per
PU approx.

(KG)


ATR007000400SA14X A 5 16.6 195*120*210 120*92 7 K 5.1
ATR010500400SA14X A 7.5 11.1 195*120*210 120*112 10 K 8.1
ATR014000400SA14X A 10 8.29 195*120*210 120*112 14 K 9.4
ATR017500400SA14X A 12.5 6.63 195*120*210 120*112 18 K 12
ATR021000400SA14X A 15 5.53 250*165*200 182*95 21 K 16
ATR028000400SA14X A 20 4.14 250*185*200 182*115 30 K 18
ATR035000400SA14B B 25 3.32 290*150*210 214*113 35 K 28
ATR042000400SA14B B 30 2.76 290*185*220 214*118 42 K 26
ATR056000400SA14B B 40 2.07 290*215*280 214*118 56 F 35.2
ATR070000400SA14B B 50 1.66 3320*230*275 243*135 70 F 37.2
ATR084000400SA14B B 60 1.38 320*230*310 243*135 85 F 51.1
ATR112000400SA14B B 80 1.04 375*250*320 260*165 110 F 54
ATR126000400SA14B B 90 0.92 375*250*320 260*165 125 F 58
ATR140000400SA14B B 100 0.829 375*265*360 260*175 140 F 62